{"product_id":"etec-electronic-protocol-epc-controller-parts-for-electric-vehicle-charging-stations","title":"ETEC Electronic Protocol EPC controller parts for electric vehicle charging stations.","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNONE\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCountry\/Region of Manufacture\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eCHINA\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eItem Height\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e5CM\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eItem Length\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e12CM\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eItem Weight\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e250G\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eItem Width\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003e9CM\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe intelligence of an AC charging station or an AC charging infrastructure is largely determined by the charge controller used. A smart charge controller has the primary task of controlling and monitoring the charging process of an electrical vehicle.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe features that characterise a smart charge controller include communication with a backend system and the associated authorisation of users, as well as the efficient distribution of load currents by means of dynamic load management to prevent an overload of the existing AC system.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eETEK Electric, according to the European standard IEC 61851-1, produced EV Charging Controller Control unit for charging electric vehicles, it can be used for charging almost all electric vehicles using both type 1 and type 2 plugs. The AC charging control unit is suitable for private and industrial applications and supports one charging point.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eDescription\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe controller is a kind of product suitable for charging pile of electric vehicle.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e(1) Software correction instructions, such as EKEPC1 or EKEPC2\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e(2) Maximum charging capacity indication 10A, 16A, 20A, 25A, 32A, Through the internal dial switch (The factory default setting is 32A)\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e(3) \"C\" for the cable version and \"S\" for the socket (without cable) version\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e(4) \"C\": with cable version\" means that the charging cable is permanently connected to the controller; Pl\/P2 terminal is connected to the AC contactor providing the charging load. The rated value of Curve B circuit breaker shall be selected within the maximum current range circuit breaker shall be selected within the maximum current range.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eTechnical Data\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S802779d462a84a5abbe084550166036fk.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eScope of use\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eControl the communication of the electric vehicle AC charging process complies with IEC 61851 or SAEJ1772 standards.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eConform to DIN EN60715 installation requirements.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe output of the relay is used to connect the AC contactor that switches on\/off the load.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe operating status of the EV interface is indicated by three-color LED lights.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe controller additional functions include: non-contact IC card connection module, DC leakage detection module (RCMU), RS485 communication interface equipment, plug lock device, external emergency stop button, etc.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eApplication cases\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe following is a schematic diagram of an application case.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eFor example, item C with 1 pes type B circuit breaker and 1 pcs contactor, item A, B with 1pcs type A circuit breaker plus RCMU module and 1 contactor.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S95082c5e04194a94baf1c12dc1e00566o.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eController charging procedure\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAfter connected on the working voltage, the controller starts to initialize (self - detection procedure on the RCMU module) and conduct self - detection function (LED cycle flashing), waiting for the car to connect. The controller waits for the charging cable and the vehicle connection (status A), and the LED keeps flashing blue light, and this process requires about 6s waiting. If this controller connected the matched cable (status B), LED becomes stable blue light (and opens the electromagnetic lock switch).\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAfter the charging plug linkage, and if the vehicle is in state C, the controller keeps the P1\/P2 closed (charger connected), the LED becomes stable green, and the EV starts into charging mode. If the display status D( requires ventilation), because the controller does not have the heat dissipation function, the controller puts the P1\/P2 on (charger off) simultaneously (close the electromagnetic lock switch), the head interlock fails and the controller turns off the charging program, the LED becomes stable red.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eTerminal description of the controller\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Se6410500771f4257821b4251a26569dco.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"color:rgb(255, 255, 255)\"\u003eFunctional grounding\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e1. Connect \"CP\" directly to the interface of vehicle charging terminal.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e2. Firstly connect the ground wire (PE line) of the vehicle charging terminal interface to the OV control point of the EPC controller, and then connect other lines in order. Do not use terminal blocks or EPC controller to connect the device from the outside at OV control point.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eOV control point shall be consistent with the expected current of the factory. The connection of EPC Controller to OV is functional grounding, and the reliability of connection must be guaranteed, otherwise personal injury or property loss will be caused.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eRelay output\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eWe recommend connection with 230\/400V 10kA curve B RCCB.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eCutting off the power branch\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eAccording to IEC61851, it is required to cut off the power branch when the charging process is completed within 100ms.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eThe EPC controller will stop the relay output after detecting that the power branch is cut off.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eReplacement device\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eTouching any running parts will cause serious injury. Please cut off the power before operation. Process:\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e1. Cut off the line from the EPC controller terminal.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e2. Pull the latch down from the back of the unit and rotate until it is free of the DIN rail and removed.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e3. Installation: connect the rear lock clipper to the DIN rail and swing until the lock clipper was put in.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e4. Reconnect the line (On).\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e5. Turn on the switch and the main power.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eWarning There is no replaceable fuse inside EPC When replacing, make sure that the device and the components associated with the device are not energized.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eDanger: Voltage hazard.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eCleaning off the unit is not allowed, EPC charging controller is maintenance free.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eController connection status\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sc922838ea5d540639f2028ae7cb829c6T.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eTerminal function description\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sf16f4c51c88a4c368e5ba3702bde608cG.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"color:rgb(68, 68, 68)\"\u003eRS485 Communication description\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"color:rgb(68, 68, 68)\"\u003eModbus-RTUmodel , Baud rate: 38400, fixed , address: 1-255default : 255（Broadcast address ）\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S00fc89bdc8ec4eedb1324ac1f079f9cfI.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eApplication circuit diagram\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/Sdcbf639a824c4450b11ecaa0b72d6e44r.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eEasy installation\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e1: Install the controller (a) vertically onto the horizontal DIN rail (b)\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003e2: Rotate the controller down until the clip into the Din\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S12fa94573a3c4568a2d6abd421e934dcH.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_text\"\u003e\u003cp style=\"font-family:OpenSans;font-size:14px;font-weight:300;line-height:20px;white-space:pre-wrap;color:rgb(0, 0, 0);margin-bottom:12px\" class=\"detail-desc-decorate-content\"\u003eOverall dimension(mm)\u003c\/p\u003e\u003c\/div\u003e\u003cdiv class=\"detailmodule_image\"\u003e\u003cimg class=\"detail-desc-decorate-image\" src=\"https:\/\/ae01.alicdn.com\/kf\/S35a4851ef6e943c0a9887960970b05466.jpg\" slate-data-type=\"image\"\u003e\u003c\/div\u003e\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"AUTENKO MOTORS","offers":[{"title":"DLB CT","offer_id":53108634485043,"sku":"14:200002130#DLB CT","price":29.26,"currency_code":"USD","in_stock":true},{"title":"LCD SCREEN","offer_id":53108634517811,"sku":"14:200003699#LCD SCREEN","price":44.85,"currency_code":"USD","in_stock":true},{"title":"RCMU","offer_id":53108634550579,"sku":"14:200004891#RCMU","price":40.01,"currency_code":"USD","in_stock":true},{"title":"Cable Ver with RFID","offer_id":53108634583347,"sku":"14:200004890#Cable Ver with RFID","price":104.84,"currency_code":"USD","in_stock":true},{"title":"Socket Ver with RFID","offer_id":53108634616115,"sku":"14:200004889#Socket Ver with RFID","price":104.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0950\/0590\/1107\/files\/S32e1f63daf99425fab4543348744b5b6O.webp?v=1772664865","url":"https:\/\/autenkomotors.com\/products\/etec-electronic-protocol-epc-controller-parts-for-electric-vehicle-charging-stations","provider":"AUTENKO MOTORS","version":"1.0","type":"link"}